<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-10 03-35-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 4/5, 57 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.4 kHz 67 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19100 0,5654
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 3,23 dBr 4,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 3:35, 10.11.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,5654 Acquired: 2025/11/10 3.34.25 Total samples: 19100 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,9 dBr MIN: 1,0 dBr AVE: 3,23 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2025/11/10 3.34.25) 03.20 03.22 03.24 03.26 03.28 03.30 03.32 03.34 0 2 4 Pm [dBr]